# How to verify data center fiber route diversity

> Check carriers by address, then verify independent entrances, fiber paths, and cloud handoffs. A Secaucus example shows what public directories can tell you.

URL: https://invariant-ai.com/blog/data-center-fiber-route-diversity  
Published: 2026-11-22 · Publisher: Invariant · Region: United States

To verify fiber route diversity at a data center, identify the exact endpoints of both circuits and ask the providers for evidence of their physical paths. Check the building entrances, internal paths, outside conduits and crossings, and where each circuit hands off to the next network. A directory can tell you which carriers or cloud services to investigate. For a lease or service commitment, document what the surviving circuit can carry when one route or facility fails.

## Key points

- Look up the exact building and service address. Record the carrier, underlying operator, connection endpoint, and whether the proposed service has been ordered or built.
- At Secaucus, Equinix lists two different building addresses, while AWS lists one Direct Connect location for the access relationship shown in this example.
- Check both route separation and surviving throughput. Two 10 Gbps circuits leave 10 Gbps of nominal capacity after a single circuit loss.

## What can you verify from a data center address?

| Question | Where to look | Evidence to keep |
| --- | --- | --- |
| Who reports service nearby? | FCC National Broadband Map for reported fixed availability and operator service maps or quotes. | Exact building, provider, technology, and date. Ask the carrier to qualify the specific service and endpoint. ([FCC](https://help.bdc.fcc.gov/hc/en-us/articles/13532984820379-What-s-on-the-National-Broadband-Map)) |
| Which network or cloud handoffs are offered? | Facility operator pages, its connectivity contacts, and the cloud provider’s location directory. | Building ID, named handoff location, connection product, underlying carrier where known, and the organization providing the interconnect. ([Equinix](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny4)) ([AWS](https://aws.amazon.com/directconnect/locations/)) ([CoreSite](https://www.coresite.com/data-center/ny1-new-york-ny)) |
| What is the physical route for each circuit? | A carrier route exhibit or a written route comparison for the proposed or installed circuits, including both endpoints. | Path and entrance identifiers, common segments, route version, associated circuit order, and the comparison scope. ([IETF](https://datatracker.ietf.org/doc/html/rfc4054)) |
| What survives a loss or scheduled maintenance? | Service terms, circuit design, equipment and port assignments, and a coordinated acceptance test. | Agreed failures to test, surviving throughput and failover behavior, observation date, exceptions, and the owner of any remediation. ([AWS](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html)) |

A carrier name by itself leaves several questions open. Ask who owns and operates the access segment and whether either provider leases facilities from the same third party. In a multi-building campus, confirm the service address, point of entry, handoff room and equipment for the specific circuit you intend to buy. ([IETF](https://datatracker.ietf.org/doc/html/rfc4054)) ([AWS](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html))

## Two Secaucus buildings, one listed AWS location

We checked Equinix’s facility pages and the AWS Direct Connect location directory on November 22, 2026. Equinix lists NY4 and NY5 at different street addresses. In the Direct Connect table, AWS lists Equinix NY5 as the location and shows that it is also accessible from NY4. AWS separately lists a CoreSite NY1 location in New York City. ([Equinix](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny4)) ([Equinix](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny5)) ([AWS](https://aws.amazon.com/directconnect/locations/)) ([CoreSite](https://www.coresite.com/data-center/ny1-new-york-ny))

| Data center | Operator-listed address | What AWS Direct Connect lists |
| --- | --- | --- |
| Equinix NY4 | 755 Secaucus Road, Secaucus, NJ | Access option for the Equinix NY5 location. ([Equinix](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny4)) ([AWS](https://aws.amazon.com/directconnect/locations/)) |
| Equinix NY5 | 800 Secaucus Road, Secaucus, NJ | Named Equinix NY5 location in Secaucus. ([Equinix](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny5)) ([AWS](https://aws.amazon.com/directconnect/locations/)) |
| CoreSite NY1 | 32 Avenue of the Americas, New York, NY | Separately listed CoreSite NY1 location. ([CoreSite](https://www.coresite.com/data-center/ny1-new-york-ny)) ([AWS](https://aws.amazon.com/directconnect/locations/)) |

The count depends on what you’re counting. For NY4 and NY5, the public records establish two buildings and one named AWS location in this comparison. If your design requires two AWS locations, use the cloud provider’s location records to choose candidates, then verify the transport from your site to each handoff. The next evidence you need is the route comparison for the two circuits you plan to order. ([AWS](https://aws.amazon.com/directconnect/locations/)) ([AWS](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html))

[Download the facility cross-reference and failover calculation (JSON)](https://invariant-ai.com/blog/data-center-fiber-route-diversity.json)

[Browse utility and infrastructure fields](https://docs.invariant-ai.com/api/field-catalog#utilities)

## How to verify two independent fiber paths

Draw the comparison from your equipment to the two remote handoffs. Check the building entrances, risers, cross-connect rooms, conduit, and any crossings where the routes could come back together. Include shared access equipment and maintenance domains where those risks matter to your design. Network engineers sometimes call links that share a physical failure risk a shared-risk link group. ([IETF](https://datatracker.ietf.org/doc/html/rfc4054))

- Ask both providers for current route exhibits or a written comparison that names the circuit orders, endpoints, and parts of the path covered. Use the providers’ agreed process for reviewing sensitive drawings.
- Ask for exceptions in writing. A shared conduit, building entrance, or wholesale local loop may affect both circuits. Identify what fails together and whether the design accepts that risk.
- Compare the installed route and endpoint records at acceptance, then track changes to the route or the facility. Confirm the contracted installation scope and any notification terms for rerouting.

Sources: ([IETF](https://datatracker.ietf.org/doc/html/rfc4054)) ([AWS](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html))

The AWS Direct Connect resiliency models also distinguish device failures from complete location failures. Pick the level of resilience your workload requires, including any separate facility or device requirements, and verify the last-mile design that connects your equipment to those AWS locations. ([AWS](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html))

## Can the surviving circuit carry the workload?

Suppose two nominal 10 Gbps circuits must carry a 15 Gbps peak workload after either one fails. With one down, 10 Gbps of nominal capacity remains and the shortfall is 5 Gbps. This example uses link rates before protocol overhead. Use measured usable capacity and your own traffic profile for procurement.

Agree on an acceptance test with the providers. Exercise each failure the contract and design are meant to cover in a coordinated window, then record which path carried traffic, the transition time, and delivered throughput at the expected load. Keep the test evidence and the route evidence together so a reviewer can see both the physical design and what happened during failover. ([AWS](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html))

**Related data center diligence guides:** [Use the data center site selection checklist](https://invariant-ai.com/blog/data-center-site-selection-checklist) · [Compare power and upgrade evidence for a campus](https://invariant-ai.com/blog/data-center-power-screening-tools) · [Compare location and infrastructure GIS data](https://invariant-ai.com/blog/best-gis-apis-for-site-selection)

## Questions

### Can I look up exact fiber routes by address?

An address lookup can identify reported providers, facilities, and cloud access locations. Ask the proposed providers for a route comparison tied to your circuit orders and endpoints. Verify building entry and shared physical segments as part of that review. ([FCC](https://help.bdc.fcc.gov/hc/en-us/articles/13532984820379-What-s-on-the-National-Broadband-Map)) ([AWS](https://aws.amazon.com/directconnect/locations/)) ([IETF](https://datatracker.ietf.org/doc/html/rfc4054))

### Do two carriers guarantee two physical fiber paths?

Check the actual routes and facility handoffs for both carriers. Different service providers can share the same underlying conduit, local access facilities, or building entrances. Ask each provider which parts of the path its diversity commitment covers. ([IETF](https://datatracker.ietf.org/doc/html/rfc4054))

### Do two 10 Gbps circuits support 15 Gbps after one fails?

On nominal rates, one surviving 10 Gbps circuit leaves a 5 Gbps shortfall against a 15 Gbps requirement. Check measured throughput and failover behavior under the workload you plan to carry.

## Sources

- FCC: [What the National Broadband Map shows](https://help.bdc.fcc.gov/hc/en-us/articles/13532984820379-What-s-on-the-National-Broadband-Map)
- Equinix: [Equinix NY4 facility information and address](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny4)
- Equinix: [Equinix NY5 facility information and address](https://www.equinix.com/data-centers/americas-colocation/united-states-colocation/new-york-data-centers/ny5)
- CoreSite: [CoreSite NY1 facility information and address](https://www.coresite.com/data-center/ny1-new-york-ny)
- AWS: [AWS Direct Connect locations and access options](https://aws.amazon.com/directconnect/locations/)
- AWS: [AWS Direct Connect Resiliency Toolkit](https://docs.aws.amazon.com/directconnect/latest/UserGuide/resiliency_toolkit.html)
- IETF: [RFC 4054, diversity and optical route constraints](https://datatracker.ietf.org/doc/html/rfc4054)

## Related

- [Data Center Site Selection Checklist and Criteria](https://invariant-ai.com/blog/data-center-site-selection-checklist)
- [Data center site selection tools for power capacity](https://invariant-ai.com/blog/data-center-power-screening-tools)
- [Best GIS APIs for U.S. site selection](https://invariant-ai.com/blog/best-gis-apis-for-site-selection)