  "title": "Building 3 elevation certificates and a county flood map point check",
  "verified_date": "2026-11-24",
  "building": {
    "label": "Airport Tract 1, Building 3",
    "street": "2519 Vacation Drive",
    "city_as_filed": "Myrtle Beach",
    "state": "SC",
    "county_permit": "136756",
    "parcel_id": "44202010022",
    "horizontal_datum": "NAD83",
    "coordinates_lon_lat": [
      -78.94172222,
      33.69489444
    ]
  },
  "certificate_packet": {
    "url": "https://www.horrycountysc.gov/media/5rgjkg35/136756-final-ecert-floodproof-certificate.pdf",
    "sha256": "21ce31ee288b7a74c1fd8bcdd7759257b1733f9a541de1285a23bfb8c7d4025d",
    "county_packet_date": "2023-07-10",
    "elevation_certificate_signed": "2022-12-14",
    "certificate_panel": "45051C0704K",
    "certificate_panel_effective_date": "2021-12-16",
    "vertical_datum": "NAVD88",
    "unit": "ft",
    "finish_status": "Finished construction"
  },
  "certificate_elevations": [
    {
      "quantity": "Base flood elevation on the certificate",
      "elevation_ft": 13.0,
      "pdf_page": 4,
      "record_field": "Elevation Certificate, B9",
      "notes": "Value copied from the mapped source for the certificate."
    },
    {
      "quantity": "Top of bottom floor",
      "elevation_ft": 14.0,
      "pdf_page": 5,
      "record_field": "Elevation Certificate, C2(a)",
      "notes": "Finished construction."
    },
    {
      "quantity": "Lowest equipment",
      "elevation_ft": 16.2,
      "pdf_page": 5,
      "record_field": "Elevation Certificate, C2(e)",
      "notes": "Air-conditioning unit on a raised stand, per the comments."
    },
    {
      "quantity": "Lowest adjacent grade",
      "elevation_ft": 10.0,
      "pdf_page": 5,
      "record_field": "Elevation Certificate, C2(f)",
      "notes": "Certificate identifies a drain at a recessed loading dock."
    },
    {
      "quantity": "Highest adjacent grade",
      "elevation_ft": 14.0,
      "pdf_page": 5,
      "record_field": "Elevation Certificate, C2(g)",
      "notes": "Finished grade."
    },
    {
      "quantity": "Certified floodproofing elevation",
      "elevation_ft": 15.0,
      "pdf_page": 1,
      "record_field": "Floodproofing Certificate, Section II",
      "notes": "Elevation recorded on the separate non-residential certificate."
    }
  ],
  "floodproofing_height_above_grade_as_written": {
    "height_ft": 1.0,
    "pdf_page": 1,
    "section": "Floodproofing Certificate, Section II",
    "note": "Retain separately. Subtracting C2(f) of the Elevation Certificate from the certified floodproofing elevation gives 5.0 ft. Ask which grade reference was used before applying a grade-relative height."
  },
  "county_point_queries": [
    {
      "layer": "Current FEMA Flood Zones",
      "url": "https://gisportal.horrycounty.org/server/rest/services/EmergencyMgmt/Current_FEMA_Flood_Zones/FeatureServer/7/query?f=json&where=1%3D1&geometry=-78.94172222%2C33.69489444&geometryType=esriGeometryPoint&inSR=4269&spatialRel=esriSpatialRelIntersects&outFields=FLD_AR_ID%2CFLD_ZONE%2CSFHA_TF%2CSTATIC_BFE%2CV_DATUM%2CLEN_UNIT&returnGeometry=false",
      "sha256": "da6a8532ac42dbf125c42771369d36b17b5aa7529fa03d55bee1f6fd39db3ba0",
      "raw_attributes": {
        "FLD_AR_ID": "1907",
        "FLD_ZONE": "AE",
        "SFHA_TF": "T",
        "STATIC_BFE": -9999,
        "V_DATUM": " ",
        "LEN_UNIT": " "
      },
      "static_bfe_ft": null,
      "note": "The raw -9999 value represents an unpopulated static elevation."
    },
    {
      "layer": "Current FEMA FIRM Panels",
      "url": "https://gisportal.horrycounty.org/server/rest/services/EmergencyMgmt/County_GISFloodMaps/MapServer/8/query?f=json&where=1%3D1&geometry=-78.94172222%2C33.69489444&geometryType=esriGeometryPoint&inSR=4269&spatialRel=esriSpatialRelIntersects&outFields=%2A&returnGeometry=false",
      "sha256": "6f15a45fd8ba50ce82953c2cd74b965f0c82e4bd974da4bdd2653e09c9e65564",
      "panel_id": "45051C0704K",
      "note": "The point matched the same panel ID as the certificate. The effective date above comes from the filed certificate."
    }
  ],
  "derived_comparisons": {
    "floor_above_certificate_bfe_ft": 1.0,
    "certified_floodproofing_above_certificate_bfe_ft": 2.0,
    "equipment_above_certificate_bfe_ft": 3.2,
    "scope": "Arithmetic on the filed NAVD88 elevations. The county point lookup supplies no current static BFE and these calculations do not establish policy terms or present condition."
  }
}