  "title": "Floodplain improvement thresholds and permit lookback example",
  "checked_on": "2026-11-24",
  "rules": [
    {
      "name": "Federal NFIP baseline",
      "improvement_threshold_percent": 50,
      "damage_threshold_percent": 50,
      "published_lookback_years": null,
      "scope": "Federal definitions. Check the jurisdiction for a cumulative period or a stricter threshold.",
      "source_id": "federal-definition"
    },
    {
      "name": "City of Miami Beach, Florida",
      "improvement_threshold_percent": 50,
      "damage_threshold_percent": null,
      "published_lookback_years": 1,
      "scope": "City Building Department’s published cumulative improvement procedure. The example uses this rule only for improvement.",
      "source_id": "miami-beach-rule"
    },
    {
      "name": "Charleston County, South Carolina",
      "improvement_threshold_percent": 49,
      "damage_threshold_percent": 49,
      "published_lookback_years": 5,
      "scope": "Special flood hazard areas within the county ordinance’s jurisdiction. Verify the administering authority for each address.",
      "source_id": "charleston-ordinance"
    }
  ],
  "source_records": [
    {
      "id": "federal-definition",
      "title": "44 CFR 59.1, federal definitions of substantial improvement and substantial damage",
      "url": "https://www.ecfr.gov/current/title-44/chapter-I/subchapter-B/part-59/subpart-A/section-59.1"
    },
    {
      "id": "fema-cost-guide",
      "title": "FEMA P-758, substantial improvement and substantial damage desk reference",
      "url": "https://www.fema.gov/sites/default/files/documents/fema_nfip_substantial-improvement-substantial-damage-desk-reference.pdf"
    },
    {
      "id": "charleston-ordinance",
      "title": "Charleston County Ordinance 2306, Sections 9-10 and 9-20, adopted August 13, 2024",
      "url": "https://www.charlestoncounty.gov/departments/building-inspection-services/files/Flood-Ordinance-2306.pdf?v=797"
    },
    {
      "id": "charleston-index",
      "title": "Building Inspection Services, current and historical flood ordinances",
      "url": "https://www.charlestoncounty.gov/departments/building-inspection-services/ordinances.php"
    },
    {
      "id": "charleston-faq",
      "title": "Hurricane planning FAQ on improvements in a flood zone",
      "url": "https://charlestoncounty.gov/departments/emergency-Management/hurricane.php"
    },
    {
      "id": "miami-beach-rule",
      "title": "Miami Beach Building Department guidance on the 50% rule and one-year cumulative period",
      "url": "https://www.miamibeachfl.gov/city-hall/building/permits/fema-50-rule/"
    },
    {
      "id": "nfip-general-policy",
      "title": "NFIP General Property Form, Section III.D, Increased Cost of Compliance",
      "url": "https://www.ecfr.gov/current/title-44/chapter-I/subchapter-B/part-61/appendix-Appendix%20A(2)%20to%20Part%2061"
    }
  ],
  "comparison_note": "Charleston County’s hurricane FAQ describes 50%. The Building Inspection Services index lists Ordinance 2306 as current. Section 9-10 uses 49%.",
  "illustrative_example": {
    "accepted_value_building_only_usd": 1000000,
    "proposed_work_usd": 430000,
    "prior_eligible_work_usd": 60000,
    "months_before_review_of_prior_work": 30,
    "assumptions": "One building with no other qualifying work. Each authority accepts the same valuation and cost inputs. Local officials make determinations for real properties.",
    "scenarios": [
      {
        "jurisdiction": "City of Miami Beach, Florida",
        "included_prior_work_usd": 0,
        "total_included_cost_usd": 430000,
        "cost_percent_of_building_value": 43.0,
        "threshold_percent": 50,
        "at_or_over_threshold": false,
        "rule_source_id": "miami-beach-rule"
      },
      {
        "jurisdiction": "Charleston County, South Carolina",
        "included_prior_work_usd": 60000,
        "total_included_cost_usd": 490000,
        "cost_percent_of_building_value": 49.0,
        "threshold_percent": 49,
        "at_or_over_threshold": true,
        "rule_source_id": "charleston-ordinance"
      }
    ]
  },
  "property_evidence_template": {
    "building_identifier": null,
    "site_address": null,
    "parcel_id": null,
    "flood_map_panel_and_effective_date": null,
    "applicable_map_change_id": null,
    "administering_authority": null,
    "ordinance_reference_and_effective_date": null,
    "improvement_threshold_pct": null,
    "permit_lookback_period": null,
    "included_permit_ids_dates_and_costs": null,
    "valuation_source_and_as_of_date": null,
    "accepted_building_only_value": null,
    "itemized_qualifying_work_cost": null,
    "written_determination_and_date": null,
    "applicable_policy_form_and_endorsements": null
  }
}